Typical Size and Weight |
| Model |
Weight
Calculation |
Examples |
| 1' Wide |
3' Wide |
6' Wide |
| CS-1100,
1101, 1102, 1103 |
0.87
x distribution tube length (in feet) + 1.65 |
2.52
lb |
4.26
lb |
6.87
lb |
| CS-2105,
2106 |
Distribution
tube length (in feet) + 2.50 |
3.50
lb |
5.50
l. |
8.50
lb |
| CS-2107,
2108 |
1.74
x Distribution tube length (in feet) + 2.50 |
4.24
lb |
7.2 lb |
12.94
lb |
|
| Model |
Weight
Calculation |
| CS-3110,
3112, 4111 |
4.64
x length of header (in feet) + (0.93 x length of distribution
tube (in feet) x number of distribution tubes) |
| CS-3115,
3117, 4116 |
6.28
x length of header (in feet) + (1.70 x length of distribution
tube (in feet) x number of distribution tubes) |
| CS-3119 |
6.28
x length of header (in feet) + (1.83 x length of distribution
tube (in feet) x number of distribution tubes) |
|
| Note:
- CS-1000
and CS-2000 series allow 2" clearance between end of tube
and wall.
- CS-3000
and 4000 allow 1/4" clearance between end of tubes and
wall.
- If more
than 1" insulation is used notify the factory for nozzle
repositioning. ONLY EXTERNAL INSULATION SHOULD BE USED IN BULK
EVAPORATION AREA!
|